GENERAL PRODUCT SPECIFICATION
Go to cover page
15 inch LCD MONITOR
TYPE : AJ6S50/02
BRAND : HP(L1502)
8639 000 15367
2004-04-23
2004-04-23
590
17
18
HP WU
HP L1502 LCD66
8. Environmental characteristics
8.1 Environmental Requirements
8.1.1 Temperature Ranges
Operating Temperature (Independent of altitude) .................................. 5
o
C to35
o
C.
Non-Operating Temperature (Independent of altitude) ......................-20
o
Cto60
o
C.
8.1.2 Humidity
Operating (non-condensing) ......................................................................... 20% to 80%
Non-Operating (38.7
o
C maximum wet bulb temperature) ......................... 5% to 90%
8.1.3 Altitude
Operating............................ 0 to 12,000 feet [3,658 m]. Equivalent to 14.7 to 10.1 psia.
Non-Operating .................. 0 to 40,000 feet [12,192 m]. Equivalent to 14.7 to 4.4 psia.
9. Reliability
9.1 Mean Time between Failure
The demonstrated MTBF shall be 80,000 hours excluding the backlight.
The backlight shall have minimum 30k hour life (50% brightness).
10. Quality assurance requirements
10.1 Lot Acceptance
According to MIL-STD-105D Control II level
AQL : 0% (critical ); 0.65% (major); 1.5% (minor)
(Please also refer to annual quality agreement)
11. Serviceability
The serviceability of this monitor should fulfill the requirements which are prescribed in
UAW-0346 and must be checked with the check list UAT-0361.
12. Agency Approvals
CCC (China), CE (Europe), CSA (Canada),
IEC950 CB Report, NOMNYCE (Mexico),
PSB (Singapore), SEMKO (Nordic), IRMA ( Argentina )
TUV (Germany), UL (USA) GOST (Russia),
B-MARK (Poland), DEMKO (Nordic), FIMKO (Nordic),