EasyManuals Logo

HP Lab Series User Manual

HP Lab Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background imageLoading...
Page #32 background image
SECTION
V
MAINTENANCE
5-1
INTRODUCTION
S-2
Upon
receipt
of
the
power supply,
the
perfonn-
ance
check
(Paragraph 5-S) should
be
made.
This
check
is
suitable
for.incoming
inspection.
If
a
fault
is
detected
in
the
power
supply
while
making
the
performance check
or
during normal
operation,
pro-
ceed
to
the
troubleshooting procedures
(Paragraph
5-51). After troubleshooting and
repair
(Paragraph
S-67), perform any
necessary
adjustments
and
cali-
brations
(Paragraph
5-6
9).
Before
returning
the
pow-
er
supply
to
normal
operation,
repeat
the
performance
check
to
ensure
that
the
fault
has
been
properly
corrected and
that
no
other
faults
exist.
Before
do-
ing
any
maintenance
checks,
turn-on
power
supply,
allow a half-hour
warm-up.
5-3
TEST
EQUIPMENT
REQUIRED
5-4
Table
5-1
lists
the
test
equipment required
to
perform
the
various
procedures
described
in
this
Section.
Table
S-1.
Test
Equipment
Required
TYPE
REQUIRED
USE
RECOMMENDED
CHARACTERISTICS
MODEL
Differential
Sensitivity:
lmVfull s-cale.(min.)
..
Measure
de
voltages:
*'
3420
V~ltmeter
Input impedance:
10
megohms
calibration
procedures
{See Note)
(min.).
Variable
Range: 90-130
Volts.
Equipped
Vary
ac
input
---
Voltage
with
voltmeter
accurate
within
l'V.
Transformer
AC
Voltmeter
Accuracy:
2%.
Sensitivity:
lmV
Measure
ac
voltages
and
~
403B
full
scale
deflection
(min.).
ripple
Oscilloscope
Sensitivity:
100.,.v/cm.
Differ-
Display
transient
response
~
140A
plus
ential
input.
waveforms
1400A plug
in.
Oscillator
Range:
5Hz
to
600KHz.
Impedance checks
~
200CD
Accuracy:
2%.
DC Voltmeter
Accuracy:
1%.
Input
resistance:
Measure de
voltages
lfi
412A
20,
000
ohms/Volt
(min~).
Repetitive Rate:
60-400Hz,
2.,.sec
rise
and
Measure
transient
See
Figure
.
5-6.
Load
Switch
fall
time.
response
Resistor
·&207B- 793.n
:1:rO.%
(3.SW
min.).
Load
resistor
---
62098-
3185./\,
±10%
(35W
min•).
Resistor
6207B-7.5.n:!:l%
3
Watts
Current sampling
See
RS4
62098-15.n
:1:1%
1.5
Watts
in
Section
VI
Resistor
llud::l%,
2
Watts
non-inductive.
Measure
impedance
---
Resistor
100
ohms,
:5%,
10
Watts.
Measure
impedance
---
5-1

Questions and Answers: