EasyManua.ls Logo

HP Lab Series - Transient Response and Preregulator Adjustments

HP Lab Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
tween
supply
and
input
power
source.
c.
Adjust
line
to
105Vac.
d.
Connect
decade
resistance
in
place
of
.R46.
e.
Turn
on
supply
and
adjust
VOLTAGE
con-
trol
for maximum
rated
output
voltage.
f.
Adjust
decade
resistance
so
that
voltage
indicated
by.
differential
voltmeter
does
not change
more
than
l.26mVdc
as
input
line
voltage
is
varied
from 105
to
125Vac.
q.
Replace
decade
resistance
with
appropri-
.
ate
value
resistor
in
R46
position.
5-85
CONSTANT
VOLTAGE
TRANSIENT
RESPONSE
5-86
To
adjust
the
transient
response,
proceed
as
follows:
a.
Connect
test
setup
shown
in
Figure
5-6.
b.
Repeat
Steps
(a)
through
(e)
as
outlined
in
Paragraph
5-31.
c~
Adjust
R3
0
so
that
the
transient
response
is
as
shown
in
Figure
5-7.
5-87
PREREGULATOR
TAACKING
5-88
To
adjust
the
prereC]Ulator,
proceed
as
fol-
lows:
a.
Connect
decade
resistanceinplaceof
R99.
b.
Turn
on
supply
and
adjust
VOLTAGE
con-
trol
for maximum
rated
output
voltage
(no
load
con-
nected).
·
c.
Connect
de
voltmeter
across
series
regu-
lator
(TP23
to
TP24).
d.
Adjust
decade
resistance
so
that
de
volt-
.
meter
reads
15Vdc.
e.
Replace
decade
resistance
with
appropri-
ate
resistor
in
R99
position.
5-16

Related product manuals