Fuser delivery assembly
NOTE: For this product, the fuser and the paper delivery components are one assembly.
Position the fuser pressure roller for removal
You must rotate the pressure roller to the correct position before removing the fuser delivery assembly.
1. When the product is in the Ready state, press and hold the Auto-On/Auto-Off (power) button for
about seven seconds or until you hear subtle movement within the product and the Ready
light
turns off.
2. Release the Auto-On/Auto-Off (power) button. The product power will be off and the fuser
pressure roller is in the removal position. Unplug the product before removing any components.
Before proceeding, remove the following components:
●
Right cover assembly. See
Right cover assembly on page 18 .
●
Left cover assembly. See
Left cover assembly on page 19.
●
Top door assembly. See
Top door assembly on page 20.
●
Rear top cover assembly. See
Rear top cover assembly on page 22.
●
Formatter (base model) or formatter and wireless PCA (plus model). See
Formatter PCA (base
model) on page 43 or Formatter and wireless PCA (plus model) on page 44.
38 Chapter 1 Removal and replacement ENWW