Low-voltage power supply assembly
CAUTION: ESD sensitive.
Before proceeding, remove the following components:
●
Input tray. See
Input tray on page 13.
●
Right cover assembly. See
Right cover assembly on page 18.
●
Left cover assembly. See
Left cover assembly on page 19.
●
Rear lower cover assembly. See
Rear lower cover assembly on page 24.
Remove the low-voltage power supply assembly
1. Remove two screws (callout 1) and disconnect one connector (callout 2).
Figure 1-57 Remove the low-voltage power supply assembly (1 of 6)
1
2
2. Release the cables (callout 1).
ENWW
Removal and replacement procedures
49