Scanner assembly
Before proceeding, remove the following components:
●
Main tray. See
Main tray on page 10.
●
Output bin extension. See
Output bin extension on page 11.
●
Left cover. See
Left cover on page 12.
Remove the scanner assembly
1. Remove one screw (callout 1), and then disconnect three FFCs (callout 2).
Figure 1-17 Remove the scanner assembly (1 of 5)
1
2
2. Remove two FFCs from the ferrite cores (callout 1).
Figure 1-18 Remove the scanner assembly (2 of 5)
1
ENWW Removal and replacement procedures 15