2. Remove four screws (callout 1), the scanner cover (callout 2) and the sheet-metal plate (callout 3).
NOTE: The scanner cover and plate are removed as one assembly.
TIP: When the cover is reinstalled, make sure that the black screws (callout 4) are installed in
the correct screw holes.
Figure 2-114 Remove the main fan (2 of 4)
1
2
3
4
3. Disconnect one connector (callout 1), and then release the wire harness (callout 2) from the guides
(callout 3).
Figure 2-115 Remove the main fan (3 of 4)
3
2
1
108 Chapter 2 Removal and replacement ENWW