Power Cord Set Requirements
Maintenance and Service Guide B–3
United Kingdom BSI 1
United States UL 2
Notes
1. The flexible cord must be <HAR> Type HO5VV-F, 3-conductor, 1.0 mm
2
conductor size. Power cord set fittings (appliance coupler and wall plug)
must bear the certification mark of the agency responsible for evaluation in
the country where it will be used.
2. The flexible cord must be Type SPT-3 or equivalent, No. 18 AWG,
3-conductor. The wall plug must be a 2-pole grounding type with a NEMA
5-15P (15 A, 125 V) or NEMA 6-15P (15 A, 250 V) configuration.
3. The appliance coupler, flexible cord, and wall plug must bear a “T” mark
and registration number in accordance with the Japanese Dentori Law.
The flexible cord must be Type VCT or VCTF, 3-conductor, 1.00 mm
2
conductor size. The wall plug must be a 2-pole grounding type with a
Japanese Industrial Standard C8303 (7 A, 125 V) configuration.
3-Conductor Power Cord Set Requirements
(Continued)
Country Accredited Agency
Applicable Note
Number
333621-001.book Page 3 Wednesday, September 17, 2003 12:24 PM