Standard Operation Procedure
Document No. : Grizzly disassembly SOP Station:
Operation Name : Ver. : Edit date:
Fixture list (Spec.) Qty
Step:
Notice: Please inform production line leader or master if you found any abnormal..
Issued:Prepared: Zhou.gui-ling
IE department
Safe
Order
Hear
Look
Do
Static
Qual
ity
Fixtur
e
Symbol
Disassembly CAM cable & DC-in cable
7(1/1)
1. Loosen DC-in cable screw *1pcs and disassembly cable from connector, then take
out DC-in cable from unit as Pic.2 showing.
❖ Torque:1.5 ± 0.2 kgf.cm
❖ screw can not be slipped.
2. Disassembly camera cable from connector as Pic.2.
1.00
Disassembly
camera cable
Pic.2
Pic.1
Take out DC-in
cable
Release screw
2020/09/15