Loading...
Removal and replacement procedures 32
8.
Remove the multibay device ejector.
To replace the component, reverse the removal procedure.
Hot-plug power supply
WARNING: To reduce the risk of electric shock, do not disassemble the power supply or
attempt to repair it. Replace it only with the specified spare part.
CAUTION: Do not attempt to remove and replace a power supply as a hot-plug procedure
unless both bays are populated with power supplies.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To remove the component:
1. Unfasten the cable management solution to access the power supply bays.
2. Disconnect the power cord.