Removal and replacement procedures 71
10.
Apply all the grease to the top of the processor in one of the following patterns to ensure even
distribution.
11. Install the heatsink.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
12. Install all components removed from the failed system board.
13. Install the access panel ("Access panel" on page 32).
14. Install the power supplies ("AC power supply" on page 39).
15. Power up the server.
After you replace the system board, you must re-enter the server serial number and the product ID.
1. During the server startup sequence, press the F9 key to access RBSU.
2. Select the Advanced Options menu.