Page #25 background imageLoading...
Page #25 background image
System Unit
Dimensions
(HxWxD)
(with feet)
14.5 x 6.9 x 16.8 in (36.7 x 17.5 x 42.6 cm)
Weight
(approximate)
Maximum
(all hard drives, power
supplies, and processors
installed)
39 lb (17.5 kg)
Minimum
(one hard drive, power
supply, and processor
installed)
23.81 lb (10.8 kg)
Input Requirements
(per power supply)
Rated Line Voltage
90 to 132 VAC,
180 to 264 VAC
Rated Input Current
6 A (at 100 VAC),
3 A (at 200 VAC)
Rated Input Frequency
47 to 63 Hz
Rated Input Power
600 W (at 100 VAC),
600 W (at 200 VAC)
Power Supply Output
(per power supply)
Rated Steady-State
Power
365 W (at 100 VAC),
365 W (at 200 VAC)
Maximum Peak Power
385 W (at 100 VAC),
385 W (at 200 VAC)
System Inlet
Temperature
Operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change
is 10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if
operating with a fan fault or above 30°C
(86°F).
Non-operating
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
Relative Humidity
(non-condensing)
Operating
10% to 90% relative humidity (Rh), 28°C
(82.4°F) maximum wet bulb temperature, non-
condensing.
Non-operating
5% to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature,
non-condensing.
Altitude
Operating
3050 m (10,000 ft). This value may be limited
by the type and number of options installed.
Maximum allowable altitude change rate is
457 m/min (1500 ft/min).
Non-operating
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500
ft/min).
Acoustic Noise
Listed are the declared A-Weighted sound power levels (LWAd) and
declared average bystander position A-Weighted sound pressure levels
(LpAm) when the product is operating in a 23°C ambient environment.
Noise emissions were measured in accordance with ISO 7779 (ECMA
QuickSpecs
HP ProLiant ML110 Generation 5
Technical Specifications
DA - 12867 U.S. QuickSpecs — Version 25 — 9-28-2009
Page 25

Other manuals for HP ProLiant ML110 Generation 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML110 Generation 5 and is the answer not in the manual?

HP ProLiant ML110 Generation 5 Specifications

General IconGeneral
Processor Sockets1
ChipsetIntel 3200
MemoryUp to 8 GB DDR2
Memory Slots4
Form FactorTower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon 3000 Sequence
StorageUp to 4 SATA drives
NetworkEmbedded NC105i PCI Express Gigabit Server Adapter
Power Supply365W
Optical DriveOptional DVD-ROM or DVD+/-RW
Expansion Slots1 PCIe x16, 2 PCIe x1, 1 PCI