Removal and replacement procedures 54
9.
Install the IPMI card.
a. Align the card with the Lights-Out 100c upgrade connector, and then firmly seat the card on
the slot (1).
b. Secure the card with the screw you removed in step 4-a (2).
10. Perform the post-installation procedure.
System battery
The server uses a nonvolatile memory that requires a battery to retain system information when power
is removed. This 3-volt 200-mAh lithium coin cell battery is located on the system board.
If the server no longer automatically displays the correct date and time, the system battery that
provides power to the real-time clock may need to be replaced. Under normal use, battery life is 5 to
10 years.

Other manuals for HP ProLiant ML110 Generation 5

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML110 Generation 5 and is the answer not in the manual?

HP ProLiant ML110 Generation 5 Specifications

General IconGeneral
Processor Sockets1
ChipsetIntel 3200
MemoryUp to 8 GB DDR2
Memory Slots4
Form FactorTower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon 3000 Sequence
StorageUp to 4 SATA drives
NetworkEmbedded NC105i PCI Express Gigabit Server Adapter
Power Supply365W
Optical DriveOptional DVD-ROM or DVD+/-RW
Expansion Slots1 PCIe x16, 2 PCIe x1, 1 PCI