Diagnostic tools 69
5.
Reboot the server.
The diagnostic screen is displayed briefly at the end of POST.
Phoenix cME FirstBIOS Pro Setup Utility
CPU Type : Genuine Intel ® CPU @ 2.3 Ghz
CPU Speed : 2.30 GHz Logical CPUs : 4 of 4 Enabled
Physical CPUs : 1 of 1 Enabled System ROM : E617 – FFFF
Installed Memory : 1024 MB Build Date : 09/10/2007
Hard Disk 1 : None Hard Disk 4 : None
Hard Disk 2 : None Hard Disk 5 : None
Hard Disk 3 : None Hard Disk 6 : None
6. Press the Pause/Break key to continue displaying the screen until another key is pressed.
7. Press any key to continue with the system bootup.
Updating the system BIOS
Perform the steps below to update the system BIOS.
1. Go to www.hp.com and download the following files to the root directory of a bootable device.
You can use a diskette, an external USB drive, or a CD/DVD.
ROMPAQ.exe
CPQSRVR2.cpu
CPQO1501.xxx
CONFIG.sys
2. Create and label a bootable ROMPAQ device using the downloaded files.
3. Reboot the server using the bootable ROMPAQ device.
4. Follow the onscreen instructions to update the system BIOS.
Recording custom Setup values
Keep a record of the custom Setup values you have set up for your system BIOS. If the custom values
ever need restoring (after a CMOS clear, for example) you must run the Setup Utility and enter these
custom settings again. Make sure to update this record whenever you make any change to these
Setup settings or install new hardware.
You can either record the Setup values manually (hard copy) or use a CMOS backup utility.
To manually record the custom Setup values:
1. Access the Setup utility.
2. Go through each menu and submenus page, and press Print Screen to make a hard copy.
3. For multiple page menus, move to each page and print each screen.
If a printer is not available, write down the values on a piece of paper. Make sure to write them
down legibly and accurately.
4. Label and date the Setup values hard copy, and then store it in a safe and accessible place,
preferably with other user documentation for your ProLiant server.