EasyManua.ls Logo

HP ProLiant ML350 G5 - Page 13

HP ProLiant ML350 G5
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
128-MB Battery-Backed Write Cache (BBWC)
NOTE:
Supports the Smart Array E200 Controller, Smart Array 641 Controller,
and Smart Array 642 Controller.
351580-B21
Ultra320 Expansion Module for SA-6402
273911-B21
64-Bit/133-MHz (PCI-X) Single Channel Ultra320 SCSI HBA G2
374654-B21
HP SC11Xe Host Bus Adapter (PCI-e)
412911-B21
NOTE:
Please see the following QuickSpecs for Technical Specifications and
additional information:
http://h18000.www1.hp.com/products/quickspecs/11943_div/11943_div.HTML
(Single Channel Ultra320 SCSI HBA)
http://h18000.www1.hp.com/products/quickspecs/11587_div/11587_div.HTML
(Smart Array 6400 Series)
http://h18000.www1.hp.com/products/quickspecs/12069_div/12069_div.HTML
(Smart Array 642)
http://h18000.www1.hp.com/products/quickspecs/12566_div/12566_div.HTML
(SC11Xe HBA)
Fibre-channel Host Bus
Adapters
NOTE:
For the complete listing of Fibre Channel Host Bus Adapters, please see:
http://h18006.www1.hp.com/storage/saninfrastructure/hba.html
HP StorageWorks FC2142SR 4Gb PCI-e HBA
A8002A
HP StorageWorks FC2242SR Dual Channel 4 Gb PCI-e HBA
A8003A
HP StorageWorks FC1142SR 4Gb PCI-e HBA
AE311A
HP StorageWorks FC1242SR Dual Channel 4 Gb PCI-e HBA
AE312A
HP StorageWorks FC2143 4Gb PCI-X 2.0 -to-Fibre Channel HBA
AD167A
HP StorageWorks FC2243 Dual Channel 4Gb PCI-X 2.0 HBA
AD168A
HP StorageWorks FC1143 4Gb PCI-X 2.0 HBA
AB429A
HP StorageWorks FC1243 Dual Channel 4Gb PCI-X 2.0 HBA
AE369A
External Storage
Enclosures
HP StorageWorks Modular Smart Arrays
HP StorageWorks Modular Smart Array 20
NOTE:
Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies
335921-B21
HP StorageWorks Modular Smart Array 20 Starter Kit
NOTE:
Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity,
redundant power supplies. Includes Smart Array 6402/128 Controller.
NOTE:
The Modular Smart Array Enclosure 20 Family supports the SATA
1.5Gb/s 3.5" Hot Plug Hard Drives.
366172-B21
HP StorageWorks Modular Smart Array 30 Single Bus
NOTE:
Rack-mountable 14 drive (SCSI) drive enclosure with single bus,
redundant power supplies.
302969-B21
HP StorageWorks Modular Smart Array 30 Dual Bus
NOTE:
Rack-mountable 14 drive (SCSI) drive enclosure with dual bus,
redundant power supplies.
NOTE:
The Modular Smart Array Enclosure 30 Family supports the Wide Ultra3,
Ultra320 Hot Plug Hard Drives
302970-B21
QuickSpecs
HP ProLiant ML350 G5 Storage Server
Product Configuration Wizard
DA - 12560 Worldwide — Version 3 — March 2, 2007
Page 13