EasyManua.ls Logo

HP ProLiant ML350 G5 - Page 28

HP ProLiant ML350 G5
30 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
System Unit - Tower
Dimensions
(HxWxD)
(with feet/bezel)
18.43 x 8.66 x 25.2 in (46.8 x 22 x 64 cm)
Weight
(approximate)
60 lb (27.24 kg) (without hard drives)
Input Requirements
(per power supply)
Rated Line Voltage
100-120 VAC / 200-240VAC
Rated Input Frequency
50 Hz to 60 Hz
Input Power
<1000W @ 90VAC
<1050W @ 115VAC
<1205W @ 180VAC
Rated Input Current
10A(100VAC),6.7A(200VAC)
BTU Rating
4112BTU/hr
180VAC
Power Supply Output
Power
(per power
supply)
Rated Steady-State
Power
800W at 120V or 1000W at 220V
Temperature Range
Operating
50° to 95° F (10° to 35° C)
(No direct sustaining sunlight)
Storage
(up to one year)
-40° to 158° F (-40° to 70° C)
Maximum Wet Bulb
Temperature
82.4° F (28° C)
Relative Humidity
(non-condensing)
Operating
10% to 90%
Non-operating
5% to 90%
Acoustic Noise
Idle Minimum
(Fixed Disk Drives
Spinning)
L
WAd (BELS)
6.0
L
pAm (dBA)
43
Operating Minimum
(Random Seeks to Fixed
Disks)
L
WAd (BELS)
6.0
L
pAm (dBA)
43
QuickSpecs
HP ProLiant ML350 G5 Storage Server
Technical Specifications
DA - 12560 Worldwide — Version 3 — March 2, 2007