50 Reference and Troubleshooting Guide
Activating Interleaving Memory
Interleaving memory functionality is automatically activated whenever two
identical DIMMs are detected in sockets 1 and 2. If sockets 3 and 4 are
populated, it must be with identical DIMMs as well. If identical DIMMs are
installed in sockets 1, 2, and 3, the system will not boot.
For more information, refer to "Server Software and Configuration Utilities (on
page 89
)" in this guide.
Hard Drive Options
Removing a Hard Drive Blank (on page 50)
SCSI Hard Drive Guidelines (on page 51
)
Installing a SCSI Hard Drive ("Installing Hot-Plug SCSI Hard Drives" on page
51
)
Installing Non-Hot-Plug Hard Drives ("Installing a Non-Hot-Plug SCSI Hard
Drive" on page 52
)
Removing a Hard Drive Blank
To remove a hard drive blank, push the lever to release the blank and pull out.
CAUTION: To prevent improper cooling and thermal damage,
do not operate the server unless all bays are populated with either a
component or a blank.