78 Reference and Troubleshooting Guide
As a general rule, a maximum of six devices may be added per channel. The
server is equipped with two integrated Ultra320 SCSI channels.
The configuration settings on each SCSI device should be set to the SCSI ID
of the bay (Bay 0 = SCSI ID 0) that it will occupy.
If only one SCSI hard drive is used, it should be installed in the lowest-
numbered bay (0).
Be sure to remove all terminating jumpers from third-party SCSI devices.
CAUTION: To prevent damage to the equipment, be sure that
the server is powered down, all cables are disconnected from the back
of the server, and the power cord is disconnected from the grounded
(earthed) AC outlet before installing devices.
CAUTION: To prevent damage to electrical components,
properly ground the server before beginning any installation procedure.
Improper grounding can cause electrostatic discharge.
Identifying SCSI Components
Hot-Plug Hard Drive SCSI Cable (on page 79)
Internal SCSI Components (on page 83
)
Media Bays and Hard Drives (on page 84
)
68-to-50 Pin SCSI Adapter (on page 84
)