Removal and replacement procedures 33
Processor and heatsink
IMPORTANT: If upgrading processor speed, update the system ROM
before installing the processor.
IMPORTANT: PPM 2 must be installed when processor 2 is installed.
The system fails to boot if the PPM is missing.
To remove a processor and heatsink:
1. Remove the access panel.
2. Disconnect the heatsink connectors from the headers on the system board.
3. Open the heatsink retaining levers.

Other manuals for HP ProLiant ML350 Generation 4p

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant ML350 Generation 4p and is the answer not in the manual?

HP ProLiant ML350 Generation 4p Specifications

General IconGeneral
Processor SocketSocket 604
ChipsetIntel E7520
Form FactorTower
Operating System SupportMicrosoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
ProcessorIntel Xeon
MemoryPC2-3200 DDR2 SDRAM
Memory Slots8
StorageSAS or SATA (depending on configuration)
Drive BaysUp to 8 hot-plug drive bays
NetworkEmbedded NC7782 PCI-X Gigabit Server Adapter
Power SupplyRedundant power supply optional
Expansion Slots6 total: 2 PCI-Express, 2 PCI-X