Hardware options installation 81
a.
Install the rack bezel (on page 25).
b. Install the access panel (on page 26).
c. Slide the server back into the rack.
23. Connect each power cord to the server.
24. Connect each power cord to the power source.
25. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
26. Do one of the following:
o For tower models, install the bezel.
o For rack models, if removed, install the security bezel ("Security bezel option" on page 47).
Six-bay LFF drive cage
To install a six-bay, LFF hot-plug drive cage in a server, a Smart array controller option and redundant power
supply option is required.
To obtain the Smart Array controller option, contact an authorized HP reseller.
To install the Smart Array controller option, see the documentation that ships with Smart Array controller
option kit.
Installing the optional LFF hot-plug drive cage
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 22).
o For rack models, if installed, remove the security bezel (on page 24).
2. Power down the server (on page 22).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. For tower models, do the following:
a. Place the server on a flat, level surface with the access panel facing up.
b. Remove the access panel (on page 25).
5. For rack models, do the following:
a. Extend the server from the rack (on page 27).
b. Remove the access panel (on page 25).
c. Release thumbscrews and remove the rack bezel.