Power Consumption in
ES mMode – Suspend
to RAM (S3)
(instantly
available PC)
< 7 W
80 PLUS_Power Supply
Power Supply
575 Watt wide-ranging, active Power Factor Correction
Operating Voltage
Range
90 – 269 VAC
Rated Voltage Range
100 – 240 VAC
118 VAC
Rated Line Frequency
50/60Hz
400Hz
Operating Line
Frequency Range
47–66Hz
393–407Hz
Rated Input Current
7A @ 100-120VAC
3 A @ 200-240 VAC
6.7 @ 118 VAC
Heat Dissipation
(configuration and
software dependent)
Typical 699 btu/hr (176 kg-cal/hr)
Maximum 2804 btu/hr (706 kg-cal/hr)
Power Supply Fan
92x25 mm variable speed
Blue Angel Compliant
(<5w in S5 – power off)
N/A
FEMP Standby Power
compliant @ 115V
(<2W in S5 – power off)
YES
Power Consumption in
ES mMode – Suspend
to RAM (S3)
(instantly
available PC)
< 7 W
ROM Features
Description
ROM Based F10 Setup
and Diagnostics
Review and customize BIOS settings
Remote System
Installation via F12
(PXE) (remote boot from
server)
Allows a new or existing system to boot over the network and download software, including the
operating system
System/Emergency
ROM Flash Recovery
with Video
Recovers corrupted system BIOS
ROM Revision Levels
Identifies system ROM revision levels and reports in ROM-based F10 setup
Version is stored in an industry standard memory location (SMBIOS) so that management
SW applications can use and report this information
System Board Revision
Level
Allows management SW to read the revision level of the system board
Revision level is digitally encoded into the hardware and cannot be modified
Auto Setup when new
hardware installed
System automatically detects addition of new hardware
Serial, Parallel, USB,
Audio, Network,
Enable/Disable Port
Control
Enable or disables serial, parallel, USB, audio, and network ports
QuickSpecs
HP xw6400 Workstation
Technical Specifications
DA - 12505 Worldwide — Version 21 — August 16, 2007
Page 26