Repair Process:
When EL capacitors damage or explode, it may lose function and cause product no
work.
The capacitors locations are identified below:
1) You must disconnect the power cord from the power source before opening the
monitor to prevent component damage.
2) Use Multimeter measure whether EL capacitors still have charge. Before repairing
must discharging it.
C605/C703/C707/C708 in following picture need to discharging.
C712
C713
Power Board