Warranty
Legrand Australia Pty Ltd warrants this product for a
period of three years from the date of purchase. These
goods come with guarantees that cannot be excluded
under the Australian and New Zealand Consumer
Laws. You are entitled to a replacement or a refund for
a major failure and for compensation for any other
reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired if the goods fails to
be acceptable quality and the failure does not amount
to a major failure. See the Warranty card enclosed
with this product for further details.
Customer Service
For all Customer Service and Technical Support
please call Monday to Friday during business hours.
Legrand Australia
1300 369 777
www.hpmlegrand.com.au
Legrand New Zealand
0800 476 009
www.hpmlegrand.co.nz
ABN: 31 000 102661
24490B
Trouble shooting suggestions
PROBLEM
LIKELY
CAUSE
POSSIBLE
SOLUTION
Light
will not
switch
on
when
there is
movement
in
detection
area.
1.
Power not available.
Check
connections, switches and fuse.
2.
Faulty globe.
Replace
globe.
3.
Incorrect wiring.
Recheck
all wiring.
4.
Controls incorrectly set.
Change
detection angle. Change light adjustment.
5.
Sensor positioned in wrong direction.
Change
position and direction of sensor.
Light
switches
on
for no
apparent
reason.
1.
Air conditioner, heater, vents in proximity of sensor.
Reposition
and redirect sensor.
2.
Animals or birds.
Possibly unavoidable.
Redirect sensor.
3.
Interference on same circuit.
Check
for arcing switches,replace noisy flouro tubesand/
or
starters. Consider connecting Light Patrol to different
circuit.
4.
Reflective objects in detection area.
Redirect
sensor and possibly reposition.
Light
will not
switch off
after
set time
has
elapsed.
1.
Light is in manual mode (not in automatic). 630/3
only
Switch
light off for at least 10 seconds then switch
back
on to return it to auto mode.
2.
Wiring is incorrect.
Recheck
wiring.
3.
The unit has been damaged due to exceeding max
load,
use of an incompatible load type or failure of the
light
fitting (such as short circuit).
Identify
and fix the cause of the failure and replace the
unit with
a new one.