EasyManua.ls Logo

HPM 630/3 User Manual

HPM 630/3
4 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Light Patrol
Cat. 630/3, 630/3A and 630/3ABL
Instruction Manual
2 Introduction
The Light Patrol Security Sensor incorporates a
passive infrared detector that reacts instantly to body
heat and movement. When it senses a person (at a
distance of up to 12 metres) it acts as a switch to turn
the lights on to which it is connected. When body heat
and movement are no longer detected, the lights
switch off after a period of time (adjustable). A built-
in photocell deactivates the motion sensor during
daylight hours if required.
The Light Patrol provides convenience, security and safety.
Convenience for family and friends, lighting their way and
making keys easier to locate. Security from intruders who
are unexpectedly blasted by light, which usually has the
effect of scaring them off. Safety by avoiding accidents
caused by unseen obstacles.
1. Do not install when it is raining.
2. Be sure to switch off power source before installing.
3. Make sure the power wiring comes from a circuit
protected by a suitable fuse or circuit breaker.
4. For outdoor installation, a location under eaves is
preferable.
5. This unit must be installed by a licensed electrician
according to local codes and regulations.
3 Features
4
Wheninstallingthesecuritysensorpay
specialattention to thesepoints
Directed at swimming pools and ponds. The movement
and reflections are likely to create nuisance switching.
Avoid, if possible, areas which are accessible to animals.
A position which is subject to drastic changesin
temperature.
In proximity of air conditioner, dryer or heater.
In direct sunlight.
5 Sensorlocationsto be avoided
Detection
Method:
Passive
infrared
Voltage
Supply:
230
-240V a.c. 50Hz
Standby
power:
0.7W
Max.
Lighting Load:
1200W
Incandescent
450VA
Fluorescent & CFL
Temperature:
-
10° C to 45° C
Detection
Range:
12m
at 24° C
Detection
Angle:
180
°
Adjustable
Angle:
180
° vertical
Auto
Stop Time:
8
seconds ± 3 seconds (min.)
7
minutes ± 2 minutes (max.)
Lux
Level:
From
3 lux to daylight
Built
-in manual
override
function:
Cat 630/3
only
Weather
protected:
IP44
1 Specifications
Question and Answer IconNeed help?

Do you have a question about the HPM 630/3 and is the answer not in the manual?

HPM 630/3 Specifications

General IconGeneral
BrandHPM
Model630/3
CategoryAccessories
LanguageEnglish

Summary

Installation Safety Precautions

Switch off power before installation

Always disconnect the power source before commencing installation to ensure safety.

Use protected circuits

Verify wiring originates from a circuit protected by a suitable fuse or circuit breaker.

Licensed electrician required

Installation must be performed by a licensed electrician following local codes.

Sensor Location Avoidance

Installation Guide

Ensure power is off

Confirm the power supply to the circuit is switched off before beginning installation.

Connect wiring

Connect the Light Patrol to the power source following the provided wiring instructions.

Wiring Instructions

Route cables and strip insulation

Route light and power cables, stripping approximately 6-8mm of insulation for terminal block insertion.

Connect power supply

Connect the neutral (N) and active (L) wires from the power source to the terminal block.

Test Mode and Adjustments

Troubleshooting Suggestions

Light not switching on

Check power availability, globe, wiring, control settings, and sensor direction for issues.