Instruction Manual
Time Delay Switch-Two Wire
CAT XLTD770/1 & TD170/1
1 Specifications (at 25°C)
2 Features
Supply voltage 230-240V a.c. 50Hz
Selectable time delay 1, 3 or 10 minutes
Max and min load See table below
Weatherproof rating IP56 (TD170/1 only)
Operating temperature 0 to 50°C
Tube Size Effective Load Tube Size Effective Load
1 x 15W 85VA 1 x 65W 170VA
1 x 20W 85VA 1 x 80W 210VA
1 x 30W 85VA 2 x 20W 185VA
1 x 40W 105VA 2 x 40W 210VA
Load type Min Load Max Load
Incandescent and
240V linear halogen
20W 600W
240V GU10 halogen downlights Not suitable*
Compact uorescent 150W** 600W
Linear uorescent
(Electronic ballast)
150W** 600W
Linear uorescent
(Magnetic ballast with power
factor correction)
40W*** 600W***
Linear uorescent
(Magnetic ballast without power
factor correction)
100VA**** 600VA****
Low voltage halogen
(Electronic transformer)
20W 600W
Low voltage halogen
(Magnetic transformer)
20W 480W
Fan motor 20VA 600VA
* GU10 240V halogen downlights can damage the time delay switch when they fail, and are therefore not recommended for use with
this product.
** Compact and linear uorescent lamps may icker in the “off” state if the minimum load requirement is not satised. A minimum
load of 10W can be achieved if a resistive load is connected in parallel with the uorescent load. This can be, for example, a resistor
or incandescent lamp rated at least 10W.
*** Power factor correction capacitors must be placed on the line side of the time delay switch. If this is not possible then they should
either be removed, or a 36W magnetic ballast should be connected in parallel with the uorescent load, to prevent damage to the
time delay switch.
**** Refer to the following table for VA ratings when power factor correction is not used:
Selectable time delay
Choose from a 1, 3 or 10 minute delay period
using the switch on the back of the unit.
Direct replacement for pneumatic switches
No change in wiring is required.
Multiple push buttons
Connect NX770M remote push buttons
as shown in the wiring diagram to enable
switching from several locations.
Illuminated push button
Push button glows red when unit is off, so
that it can easily be located in the dark. Not
available for remote push buttons.
Weatherproof (TD170/1 only)
Rated IP56.
Ease of installation
XLTD770/1 and TD170/1 fit all standard
mounting accessories.