After-Sales Service
15
Compressor shakes
erratically and is making
loud noises.
Check for low voltage while
compressor is running.
Gauge of supply wires to
circuit possibly
undersized.
Replace the supply wires
by a qualified electrician.
Check for clogged air filter.
Air filter in need of
replacement.
Clean or replace air filter.
Do not wet the filter!
Section 5 After-Sales Service
If you need any support, or have questions about the system, please
contact our Technical Support team via hqua_qin@163.com and we will be
glad to assist you. We sincerely hope that you enjoy the benefits of clean
and safe drinking water after the installation of HQUA disinfection system.