EasyManua.ls Logo

HT Italia HT14D User Manual

HT Italia HT14D
2 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
HT14D
Release EN 1.00 - 26/11/2014
EN - 1
HT14D POCKET DIGITAL MULTIMETER
User manual
1. SAFETY PRECAUTIONS AND PROCEDURES
Avoid doing that in humid or wet places
Avoid doing that in rooms where explosive gas, combustible gas, steam or excessive dust is present
Keep you insulated from the object under test
Do not touch exposed metal parts such as test lead ends, sockets, fixing objects, circuits etc
Avoid doing that if you notice anomalous conditions such as breakages, deformations, fractures, leakages of battery liquid, blind
display etc
Be particularly careful when measuring voltages exceeding 20V to avoid risks of electrical shocks
The following symbols are used:
CAUTION - refer to the instruction manual - an improper use may damage the instrument or its components
Double insulated meter
AC Voltage
DC Voltage or Current
CAUTION: this symbol indicates that equipment, the battery and its accessories shall be subject to a separate collection
and correct disposal
2. GENERAL DESCRIPTION
The HT14D instrument performs the herewith measurements:
DC Voltage AC sine voltage
Detection of AC voltage without contact
DC Current Resistance
Diode test
9V battery test
3. INSTRUMENT DESCRIPTION
CAPTION:
1. LCD display
2. ON/OFF key
3. HOLD key
4. Functions selector
5. COM input jack
6. VmAA
input jack
7. Red LED for AC voltage detection
8. Battery cover
Fig. 1: Instrument description
4. OPERATING INSTRUCTIONS
4.1. DC VOLTAGE MEASUREMENT
1. Switch on the desired measurement range among the options: 200mV , 2000mV , 20V , 200V , 500V
2. Insert the test leads into the jacks, the red plug into VmAA
jack and black plug into COM jack and connect the red and black
test leads to the positive and negative poles of the circuit under test respectively. The voltage value is displayed. Press the HOLD
key to fix the result at display. The symbol "-" on the instrument display indicates that voltage has opposite direction with regard to
the connection performed
3. If the message "OL" is displayed the higher range is reached
4.2. AC VOLTAGE MEASUREMENT
1. Turn on the instrument in any position of the rotary switch, approach it closest to AC source and note the turn on of red LED which
is placed to the top (see Fig.1 – part 7) which detect the AC voltage
2. Switch on the desired measurement range between the options: 200V
, 500V
3. Insert the test leads into the jacks, the red plug into VmAA
jack and black plug into COM jack and connect the red and black
test leads to the circuit under test. The voltage value is displayed. Press the HOLD key to fix the result at display
4. If the message "OL" is displayed the higher range is reached
Question and Answer IconNeed help?

Do you have a question about the HT Italia HT14D and is the answer not in the manual?

HT Italia HT14D Specifications

General IconGeneral
BrandHT Italia
ModelHT14D
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety Precautions and Procedures

General Safety Precautions and Symbols

General safety precautions for use and explanation of instrument symbols.

General Description

Instrument Measurement Capabilities

Lists the various measurement functions performed by the HT14D multimeter.

Instrument Description

Instrument Components and Controls

Identifies and describes the physical parts and controls of the HT14D multimeter.

Operating Instructions

DC Voltage Measurement

Procedure for measuring DC voltage using the HT14D multimeter.

AC Voltage Measurement

Procedure for measuring AC voltage using the HT14D multimeter.

DC Current Measurement

Procedure for measuring DC current using the HT14D multimeter.

Resistance Measurement

Procedure for measuring resistance using the HT14D multimeter.

Diode Test

Procedure for performing a diode test with the HT14D multimeter.

Battery Test

Procedure for testing a 9V battery using the HT14D multimeter.

Battery Replacement

Battery Replacement Procedure

Steps for replacing the battery in the HT14D multimeter.

Internal Fuse Replacement

Internal Fuse Replacement Procedure

Steps for replacing the internal fuse in the HT14D multimeter.

Technical Specifications

Technical Specifications and Accuracy

Details on the HT14D's accuracy, ranges, and measurement capabilities.

General Specifications

General Specifications Overview

General specifications including input impedance, display type, power, and safety ratings.

Related product manuals