9
The WebUI screenshots are for reference only.
1. Set the IP address for the PC in the same network segment as the SmartLogger IP address.
Port
IP Settings SmartLogger Default Value Example of PC Settings
LAN port
IP address 192.168.8.10 192.168.8.11
Subnet mask 255.255.255.0 255.255.255.0
Default gateway 192.168.8.1 192.168.8.1
WAN port
IP address 192.168.0.10 192.168.0.11
Subnet mask 255.255.255.0 255.255.255.0
Default gateway 192.168.0.1 192.168.0.1
6
WebUI Deployment
2. Enter https://
XX.XX.XX.XX
in the address box of the browser (
XX.XX.XX.XX
is the IP address
of the SmartLogger). If you log in to the WebUI for the first time, a security risk warning is
displayed. Click Continue to this website.
When the IP address of the WAN port is in the network segment from 192.168.8.1 to
192.168.8.255, set the default gateway to 192.168.8.1 and the IP address of the LAN port to
192.168.3.10. If the connected port is a LAN port, adjust the network configuration of the
PC accordingly.
It is recommended that the PC be connected to the LAN port on the SmartLogger or the GE
port on the SmartModule. When the PC is connected to the GE port on the SmartModule,
adjust the network configuration of the PC to the configuration mode when the PC is
connected to the LAN port on the SmartLogger.
3. Select a desired language.
4. Specify the User Name and Password according to the following table, and then click Log In.
If… Then…
On the login page, the
User Name is admin by
default.
1. Enter the initial password Changeme in Password and click Log
In.
2. Change the initial password as prompted and use the admin user
name and the new password to log in again.
On the login page, the
User Name is empty by
default.
Select installer in User Name, set the login password as prompted,
and click Log In.
Protect the password by changing it periodically, and keep it secure. If you lose the
password, the device must be restored to its factory settings. The Company will not be held
liable for any losses resulting from improper password management.
You will be locked out for 10 minutes after five failed password attempts in 5 minutes.
A dialog box with recent login information is displayed after login. Click OK.
Update the SmartLogger software as required. Contact the Company's engineers to obtain
the update package and guide and complete the update accordingly.