HUAWEI 30 mm × 30 mm LGA Module
Hardware Migration Guide
Overview
HUAWEI Proprietary and Confidential
Copyright © HUAWEI Technologies Co., Ltd.
10
Table 1-2 Overview of Huawei 30 mm × 30 mm LGA modules
Product
Interface
Temperature
Dimension (mm)
MU509
1 x USIM
1 × 8 wire UART
1 × USB (Full Speed)
2 × Microphone in
1 × Handset out
1 × Speaker out
1 × PCM
8 × GPIO
2 × LED
1 × JTAG
1 ×WAKEUP_IN
1 ×WAKEUP_OUT
1 × Antenna
Normal operating
temperature: 20°C
to +70°C
Extended operating
temperature: 40°C
to +85°C
Storage
Temperature: 40°C
to +85°C
Only for MU509-
65: Normal
operating
temperature:
30°C to +75°C
30 × 30 × 2.6
MC509
1 x UIM
1 × 8 wire UART
1 × USB (Full Speed)
2 × Microphone in
1 × Handset out
1 × Speaker out
1 × PCM
7 × GPIO
2 × LED
1 × JTAG
1 × Wakeup_In
1 × Wakeup_Out
1 × W_DISABLE
3 × Antenna
Normal operating
temperature: 20°C
to +70°C
Extended operating
temperature: 30°C
to +75°C
Storage
Temperature: 40°C
to +85°C
30 × 30 × 2.65
MU609
1 x USIM
1 × 8 wire UART
1 × 2 wire UART (Debug)
1 × USB (High Speed)
5 × GPIO
1 × LED
1 × JTAG
1 × Wakeup_In
1 × Wakeup_Out
1 × SLEEP_STATUS
3 × Antenna
Normal operating
temperature: 20°C
to +70°C
Extended operating
temperature: 40°C
to +85°C
Storage
Temperature: 40°C
to +85°C
30 × 30 × 2.27