10 ELECTRICAL
DISTRIBUTOR SPECIFICATIONS
Make Delco-Remy
Model 1110887
Rotation L.H. CCW.
Point Opening .016"
Cam Angle 28°-32° (Set to 30° )
Breaker Lever Tension 19-23 Ozs.
Condenser Capacity .18-.23 Mfd.
Centrifugal Advance
(Engine Degrees and R.P.M.)
Start
Intermediate
Intermediate
Maximum
0-4°
15-19°
24-28°
34-38°
700 R.P.M.
1550 R.P.M.
2600 R.P.M.
3800 R.P.M.
Vacuum Control
(Engine Degrees and Inches
Mercury)
Start
Full Advance
Maximum Engine Degrees
1116117 Delco-Remy
5"-7"
14.25-15.75
20°
SPARK PLUG SPECIFICAITONS
Make Auto-lite Champion
Model AL-7 H-10
Thread 14 M.M. 14 M.M.
Gap .035" .035"
Torque 30 Ft. Lbs. 30 Ft. Lbs.