ELECTRICAL
9
VOLTAGE AND CURRENT REGULATION
With
Air Conditioning
Without
Air Conditioning
Make Delco-Remy Delco-Remy
Model 1119168 1119003
Cutout Relay Closing Voltage 11.8-13.5 11.8-13.5
Air Gap .020" .020"
Point Gap .020" .020"
Voltage Regulator Volts 13.8-14.8 13.8-14.8
Air Gap .075" .075"
Current Regulator Amperes 32-37 27-33
Air Gap .075" .075"
STARTING MOTOR SPECIFICATIONS
Make Delco-Remy
Model 1107648
Brush Spring Tension 35 Oz. Min.
No Load Test Amperage Draw 75 Maximum
Volts 10.3
R.P.M. 6900
SOLENOID SWITCH
Model 1119760
Hold-in Winding 18-20 Amperes at 10 Volts
Both Windings 72-76 Amperes at 10 Volts