EasyManuals Logo

Hudson 1957 User Manual

Hudson 1957
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
ELECTRICAL
9
VOLTAGE AND CURRENT REGULATION
With
Air Conditioning
Without
Air Conditioning
Make Delco-Remy Delco-Remy
Model 1119168 1119003
Cutout Relay Closing Voltage 11.8-13.5 11.8-13.5
Air Gap .020" .020"
Point Gap .020" .020"
Voltage Regulator Volts 13.8-14.8 13.8-14.8
Air Gap .075" .075"
Current Regulator Amperes 32-37 27-33
Air Gap .075" .075"
STARTING MOTOR SPECIFICATIONS
Make Delco-Remy
Model 1107648
Brush Spring Tension 35 Oz. Min.
No Load Test Amperage Draw 75 Maximum
Volts 10.3
R.P.M. 6900
SOLENOID SWITCH
Model 1119760
Hold-in Winding 18-20 Amperes at 10 Volts
Both Windings 72-76 Amperes at 10 Volts

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hudson 1957 and is the answer not in the manual?

Hudson 1957 Specifications

General IconGeneral
BrandHudson
Model1957
CategoryAutomobile
LanguageEnglish

Related product manuals