EasyManua.ls Logo

Human Touch AcuTouch 6.0 - Backrest Recline;Incline; Foot and Calf Massager Deploy;Retract

Human Touch AcuTouch 6.0
6 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
AcuTouch 6.0 Troubleshooting Guide 3
Step 3: If the chair is still not receiving power, replace the
main PCB board
If this still does not solve the problem, replace the chair.
Backrest Recline/Incline
The remote beeps once when Recline/Incline buttons are
pushed:
If you hear a single beep when you push the Recline and Incline
buttons, it means the backrest actuator is receiving power. Therefore the
actuator itself is not working properly. Replace the backrest actuator.
The remote beeps twice when Recline/Incline buttons
pushed:
If the backrest is in a fully inclined position and you hear two beeps
when you push the Recline button, it means the safety sensor has likely
failed.
1. Make sure that nothing is pressing on the safety sensor.
2. Tap the safety sensor with your foot to ensure that it didn’t get stuck
during shipping.
3. If the problem still exists, replace the safety sensor cover.
Foot and Calf Massager Deploy/Retract
The foot and calf massager will not retract the last few
inches into the chair base
Make sure the massager is not in the extended-length position (it must
be returned to default position before retracting it).
The foot and calf massager will not raise or lower at all,
and the remote beeps when you push the legs up and legs
down buttons on the controller.
Replace the foot-and-calf massager actuator.
If replacing the actuator does not solve the problem, replace the main
PCB.