5©2010 Hunter Fan Co.  42018-01   20100609
CHANGING THE HEPA FILTER
When the filter exceeds 8000 hours 
(approximately 1 year of use), the Filter Life 
Counter will display 0% life remaining and the 
Filter indicator will flash. This is a reminder 
that you should check the filter and replace 
if necessary. The proper time to change the 
filter depends on usage and the environment. 
Use the following list to help determine if the 
filter should be changed:
• Compare the color of the filter to the color 
coded chart on the inside of the housing. If 
the filter color matches the darkest color on 
the chart, you should replace the filter.
• If you notice a decrease in air output or 
an increase in noise at any time during 
normal operation, the filter may be clogged. 
Replace the filter to return to normal 
operation.
To change the filter and reset the Filter Life 
Counter:
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill. Place your 
fingers in the recesses on either side of the 
top of the grill and pull firmly. 
3. Gently pull on the filter to remove it from 
the unit. While removing the filter, note the 
directional arrows printed on the side of the 
filter. The new filter will be installed with the 
same orientation. Once removed, the used 
filter can be discarded. 
4. Remove the new filter from its wrapping 
and look at the directional arrows printed 
on the side of the filter. Install the filter with 
arrows pointing towards the unit. Press 
the filter firmly into the air purifier. To avoid 
damaging the filter media, you should press 
on the frame of the filter only.
5. Reinstall the grill by first lining up the tabs 
on the bottom of the grill with the openings 
on the air purifier base and then pushing 
the top of the grill forward until it is closed. 
CHANGING THE PREFILTER
When the Pre-Filter exceeds 2000 hours 
(refer to Filter Life Counters for additional 
information), the Pre-Filter Life Counter will 
display 0% life remaining and the Pre-Filter 
indicator will flash as a reminder that you 
should replace the pre-filter. To maintain 
proper odor-removing capability and overall 
filtration performance, the pre-filter should be 
changed every 2000 hours (approximately 3 
months of use). If necessary, the pre-filter can 
be changed more often. Proper maintenance 
of the pre-filter will help extend the life of the 
HEPA filter.
1. First, turn off and unplug the air purifier.
2. Next, remove the front grill.  Place your 
fingers in the recesses on either side of the 
top of the grill and pull firmly. 
3. The pre-filter is attached to the inside of the 
grill with hook tape. Pull gently on the pre-
filter to remove it.
4. If needed, use a soft damp cloth to wipe off 
the grill.
5. Install the new pre-filter by placing it in the 
grill and pressing gently on the pre-filter so 
that it adheres to the hook tape. You may 
notice a few black particles coming off the 
pre-filter. Those particles are part of the 
odor-removing activated carbon and will be 
collected on the filter during regular use.
6. Install the grill back onto the unit. First, line 
up the tabs on the bottom of the grill with 
the openings on the purifier base and then 
push the top of the grill forward until it is 
closed. 
7. Plug in the air purifier.
NOTE: This unit will not operate unless the 
grill is in the correct position. 
8. Finally, reset the Pre-Filter Counter by 
pressing the PRE-FILTER RESET key for 2 
2. To unlock the key pad, press and hold 
the UP/DOWN keys simultaneously for 
2-3 seconds. The Keypad Indicator will 
disappear and the keypad will be functional.
seconds. The Pre-Filter Counter will return 
to 100% and the Pre-Filter indicator will 
stop flashing.