6©2010 Hunter Fan Co.  42018-01   20100609
TROUBLESHOOTING
NOTE: To avoid risk of electric shock, always 
unplug the unit before cleaning.
1. Clean the outside of the unit with a soft, 
damp cloth. The front grill can be cleaned 
in soapy water after it has been removed 
from the unit and the pre-filter has been 
removed. See Figure 1. 
NOTE: Ensure the grill is completely dry 
before reinstalling it on the unit. Failure to do 
so could cause damage to the filters or motor.
2. At least every 90 days, open the front grill, 
remove the carbon pre-filter, and replace it. 
This is necessary to maintain proper odor-
removing and overall filtration performance. 
If necessary, it can be changed more 
often. Remember to change the Pre-Filter 
Calendar Dial to reflect the new  
Pre-Filters installation to remove any plastic 
wrapping that may be on the new filter 
before you place it into the Air Purifier.
3. The HEPA filter should be removed every 
12 months of use and matched to the 
color indicator on the inside of the filter 
compartment. When the filter matches the 
dark, charcoal gray indicator, it should be 
replaced. Your new HEPA filter will have an 
arrow on the side to indicate air flow and 
the direction the filter should be placed in 
the unit.
NOTE: This unit will not operate unless the 
grill is in the correct position.
MAINTENANCE
6. Plug in the unit. 
NOTE: This unit will not operate unless the 
grill is in the correct position.
7. To reset the filter counter, press the FILTER 
RESET key for 2 seconds. The Filter 
Counter will return to 100% and the Filter 
indicator will stop flashing.
Problem:
  No display or operation.
     Solution:
  • Confirm that the unit is plugged in.
  • Check the installation of the front    
    grill.
  • Reset the air purifier by unplugging  
     it for 30 seconds.
Problem:
  Keypad does not work.
     Solution:
  • Key pad has been locked to    
    prevent accidental changes to the   
    programs.
 
Problem:
  Erratic Display or Operation.
     Solution:
  • Reset the air purifier by unplugging  
     it for 30 seconds.
Problem:
  Filter and/or Pre-filter Indicator is    
  Flashing.
     Solution:
  •The Filter and/or Pre-Filter Life
    Counters have reached the    
    estimated usage times. Check and  
    replace filters if needed.
Problem:
  HEPA Filter and/or Carbon Pre-Filter  
  Life Counter is flashing 0%.
     Solution:
  • The Filter and/or Pre-Filter    
    Life Counters have greatly    
    exceeded the estimated usage    
    times. Check and replace the
    corresponding filters.
Problem:
  Unit has reduced air flow or    
  increased noise.
     Solution:
  • The filter is clogged and should be 
    changed.