Problem Possible Cause Solution
The thermal overload protector
cuts out repeatedly.
There is low voltage from
the power source.
Call an electrician.
There is a lack of proper
ventilation, or the room
temperature is too high.
Move the compressor to a well-ventilated
area.
The wrong gauge wire or
length of extension cord is
being used.
Check for proper gauge wire and cord
length.
The air receiver pressure
drops when the compressor
shuts off.
The connections (fittings,
tubing, etc.) are loose and
leaking.
Check all connections with a soap and
water solution and tighten.
The drain valve is loose
or open.
Tighten the drain valve.
The check valve is leaking. Bring the compressor to a service center.
There is excessive moisture
in the discharge air.
There is excessive water in
the air tank.
Drain the tank.
The compressor is working
under a high humidity
environment.
Move the compressor to an area of less
humidity; use an air line filter.
The compressor
continuously runs.
The pressure switch is
defective.
Bring the compressor to a service center.
An excessive amount of air
is being used.
Decrease the air usage; the compressor
is not large enough for the tool’s
requirement.
The air output is lower than
normal.
The inlet valves are broken. Bring the compressor to a service center.
The connections (fittings,
tubing, etc.) are loose and
leaking.
Tighten the connections.
Troubleshooting (continued)