Fuel System
Install choke (1) and throttle (2) assemblies.
Install needle valve (3), spring (4), lever (5) and
pin (6). Secure with screw
(7).
Metering lever must be level with metering
diaphragm mounting area of carburetor. Adjust
if necessary.
Install metering diaphragm and gasket. (Be
sure diaphragm is captured on needle lever.)
Install metering diaphragm cover with ventila-
tion hole facing cylinder. Secure with screws.