MK/MV-Medium Profile Series Unit Coolers (E206993_J)
Part Number: E206993_M

Table of Contents

Questions and Answers

  • A
    Antonio ParkerAug 5, 2025
    What to do if fans will not operate in Hussmann KRACK MK?
    • M
      Michael PattersonAug 5, 2025
      If the fans in your Hussmann Cooling boxes aren't working, there could be several reasons. First, check the wiring to ensure the unit is properly connected. If the wiring is correct, the motor might be defective and need replacement. Another possibility is a defective defrost timer, termination thermostat, or fan delay switch, in which case you should replace the faulty component. Also, if the room temperature is too high for the fan delay switch, try jumpering the fan delay switch terminals F to B.
  • J
    jeanette41Aug 12, 2025
    Why is ice forming on the ceiling of my Hussmann KRACK MK?
    • G
      Gregory HodgeAug 12, 2025
      Ice forming on the ceiling of your Hussmann Cooling boxes can occur for a couple of reasons. One reason is that there are too many defrost cycles happening each day. To address this, observe the frost buildup on the coil and adjust the timer to reduce the number of defrost cycles per day. Another cause could be a defective termination thermostat or defrost timer, which would require replacing the defective component.
  • P
    Patricia NolanAug 19, 2025
    What to do if there is excessive buildup of frost on the coil in Hussmann KRACK MK Cooling boxes?
    • S
      sharonphillipsSep 12, 2025
      Excessive frost buildup on the coil in your Hussmann Cooling boxes can be due to a few reasons. It could be that there are too few defrost times, in which case you should add more defrost cycles to the timer. Alternatively, the defrost cycle might be too short, so you should extend the defrost time on the timer. Also, high humidity in the cooler can cause this issue; try to limit access to the cooler and avoid propping doors open during stocking.
  • R
    Robert HensleyAug 27, 2025
    How to fix accumulation of ice in drain pan of Hussmann KRACK MK Cooling boxes?
    • F
      frodriguezAug 27, 2025
      If you notice ice accumulating in the drain pan of your Hussmann Cooling boxes, it's likely due to one of two issues. First, the drain line might be plugged, so try cleaning the drain line. If the drain line isn't the problem, the heater might be defective and require replacement.

Summary

PIPING INSTALLATION

REFRIGERATION PIPING

Conformance to codes, line sizing, and piping techniques for refrigerant systems.

EXPANSION VALVE

Instructions for installing and adjusting the expansion valve for optimal performance.

ELECTRICAL

FIELD WIRING

Safety and requirements for connecting power supply and field wiring.

AIR DEFROST SEQUENCE OF OPERATION

ELECTRIC DEFROST SEQUENCE OF OPERATION

SEQUENCE OF OPERATION

Details the normal refrigeration cycle and defrost cycle steps.

GAS DEFROST SEQUENCE OF OPERATION

UNITS WITH KE2 EVAP OEM CONTROLLER

DEFROST OPERATION

Explains the controller's defrost approach and key parameters.

START UP

PRE-STARTUP

Checks to perform before placing the system into operation.

OPERATION CHECKOUT

Verifying system functions after startup.

TROUBLESHOOTING CHART

UNIT TROUBLESHOOTING GUIDE

Lists common problems, causes, and corrective actions.

KE2 OEM EVAP TROUBLESHOOTING CHART

KE2 CONTROLLER TROUBLESHOOTING

Details specific alarms, parameters, and corrective actions for the KE2 controller.

REPLACEMENT PARTS LIST

Hussmann KRACK MK Series Specifications

General IconGeneral
BrandHussmann
ModelKRACK MK Series
CategoryCooling boxes
LanguageEnglish