SMGT Data Sheet
Engineering
Plan Views
C
L
(See Note*)
25
5
/
8
(651)
25
5
/8
(651)
Legs
28
3
/
4
(730)
Front
Refrigeration
Outlet
Water Seal
Waste Outlet
Leg Center Lines
Electrical
44
5
/8
(1133)
33
3
/
8
(849)
(See Note**)
SMBT
SMGT
SSGT
A
B
D
C
E
Meat & Delicatessen
Flat Hinged Glass
Models
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Dimensions shown as in. and (mm).
4 ft 6 ft 8 ft 12 ft
General
(A) Case Length* 48
1
/
4 (1226) 72
1
/
4 (1835) 96
3
/
8 (2448) 144
1
/
2 (3670)
Maximum O/S dimension of case back to front 44
5
/8 (1134) 44
5
/8 (1134) 44
5
/8 (1134) 44
5
/8 (1134)
(Note: Includes bumper)
Back of case to front of splashguard 33
3
/8 (848) 33
3
/8 (848) 33
3
/8 (848) 33
3
/8 (848)
Center of rear legs to center of front legs 25
5
/8 (651) 25
5
/8 (651) 25
5
/8 (651) 25
5
/8 (651)
Each End and Partition adds 1
1
/
2 in. (38 mm) to the length of the lineup.
Electrical Service
(B) RH end of case to Electrical raceway right edge 7 (178) 7 (178) 7 (178) 7 (178)
(C) RH end of case to Electrical raceway left edge 41
3
/8 (1051) 32
3
/4 (831) 44
1
/2 (1131) 44
1
/2 (1131)
Back of case to center of knockout 3
5
/8 (92) 3
5
/8 (92) 3
5
/8 (92) 3
5
/8 (92)
* Electrical Field Wiring Connection Point
Waste Outlet
(D) RH end of case to the center of waste outlet 24 (610) 24 (610) 24 (610) 24 (610)
Back of case to center of waste outlet 25
5
/8 (652) 25
5
/8 (652) 25
5
/8 (652) 25
5
/8 (652)
Water Seal
Center of tee to center of waste outlet 11
3
/8 (289) 11
3
/8 (289) 11
3
/8 (289) 11
3
/8 (289)
Outside diameter of drip piping 1
1
/2 (38) 1
1
/2 (38) 1
1
/2 (38) 1
1
/2 (38)
** Field installed water seal outlets, tees, and connectors are shipped with the merchandiser.
Refrigeration Outlet
Back of case to center of refrigeration outlet 28
3
/4 (731) 28
3
/4 (731) 28
3
/4 (731) 28
3
/4 (731)
(E) RH end of case to center of refrigeration outlet 9
3
/8 (238) 9
3
/8 (238) 9
3
/8 (238) 9
3
/8 (238)
Outside diameter of the liquid line
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
3
/8 (9.5)
Outside diameter of the suction line
5
/8 (16)
5
/8 (16)
5
/8 (16)
5
/8 (16)
2 of 6