4 - 12
Format efault
Setting , Motor rotates in the positive direction. C
Setting 1, Motor rotates in the negative direction. CC
This MCM can be used to reverse the direction of motor rotation if desired. So
These parameters will affect the direction of OM position
30. -oming speed-1
31. --oming speed-1
32. -oming speed-1
Format default value: 25, unit: mm/min
In the homing process, the speed for an aial movement from the current position
to the position where the origin-switch is touched.
33. -oming speed-2
34. -oming speed-2
35. -oming speed-2
Format default value: 4, unit: mm/min
The speed the feedback device searches for rid ero after the aial position
leaves the origin-switch in the homing process.
Items reuiring the attention of the user; in the homing process, the machine
moves toward the origin-switch with the first-stage speed, the length of the
origin-switch must be longer than the deceleration distance, otherwise the
machine will eceed the proimity switch and this results in a OMI error.
The formula and an eample for calculating the length of origin-switch are as
follows:
Length of origin switch FDCOM CC 6
ote: FCOM First-stage speed of homing
ACC Accelerate/ decelerate time of 1