4 MCM Parameter Settings
4 - 23
Format default value: .
Setting : Tool Row
Setting 1: lectrical Turret
Setting 2: ydraulic Turret
Setting 3: lectrical Turret 2
82. Setting of Tool positioning delay
Format default value: 1, unit: 1 ms
efault setting is 1, i.e., 1 ms.
In the event of miss-positioned tool change, properly increase this parameter
setting and observe if the tool change is better positioned.
83. Tool Change monitoring time setting
Format
Such parameter is used to monitor the time consumed during the entire Tool
change process. If the actual Tool change time eceeds the set value of such
parameter, then the screen will indicate “Tool Change Overdue” alarm signal. To
remove the alarm, please refer to the function alarm described in Chapter 6.
84. Setting of wear direction
Format default value: 1, positive
Setting , negative direction
Setting 1, positive direction
User may make adustment according the used direction for making compensation
for the wear.
85. Setting of maimum value of tool compensation
Format . default value: 2.; maimum value is 2., unit: mm
This setting is used for setting an upper limit for the tool compensation when the
program is not in eecution. In case eceeding the upper limit, an alarm
86. Setting of lubrication interval
Format default value: 1, unit:1s
87. Setting of lubrication duration