UST CC6-T Manual
4 - 3
In this case, the Spindle Chuck action is controlled by O independently.
I 2-way Solenoid alve
In this case, the Spindle Chuck action is ointly controlled by O and O5.
117. and heel Test Feed Rate umerator
118. and heel Test Feed Rate enominator
Format default value: 1
It is used to adust the fast/slow program feed rate when testing the and heel.
* Parameter for switching the Spindle back to standard axis
119. Set the Rotation irection
Format default value:
Setting : Forward direction
Setting 1: Reverse direction
120. Set the Acceleration/eceleration Time
Format
Setting Scope: 43 ms
121. Maimum feed speed
Format default value: 1, unit: mm/min
ote: Setting value shall be an integer without a decimal point.
.g.: Setting 5, indicates a maimum -ais feed rate of 5mm per
minute.
imit of ma. feed speed is calculated as follows:
Fma .5
: -ais servomotor ma. speed is 3 rpm, guide screw is 5 mm, gear
ratio is 5 1 servomotor turns 5 revolutions, guide screw turns 1
revolution
Fma 25. Recommended setting is 25.
122. Set Spindle ncoder Multiple
Format default value: 4
Setting 1: Means feedback signal multiplied by 1.
Setting 2: Means feedback signal multiplied by 2.