HUST CNC H6D-T Manual
5 - 26
(d) 8 Out AC power boards.
(e) 8 Out Axis Control Modules: To control the Servo or Step Motor.
3. When using with Universal Auxiliary Panel, it will occupy the I/O position of
Panel 2.
4. The Dip Switch is used to define the I/O starting position of SIO Module Board.
Explanation of SIO MODULE BOARD
LED-lamp (Input)
LED-lamp (Output)
SWITCH
Fig.5-31
1. LED Indicator:
I-Point Signal LED Indicator (Green) : 3 groups each for upper and lower rows
with each group containing 8 lamps, which makes a total of 48 lamps.
O-Point Signal LED Indicator (Red) : 2 groups each for upper and lower rows
with each group containing 8 lamps, which makes a total of 32 lamps.
2. Dip Switch : For setting the SIO Module Board and I/O
staring signal position.
LED
24V external power input
Group 1 CONNECT board
port
LED
Group 2 CONNECT board
port
ON DIP
1 2 3 4
SW