5 Connections
5 - 27
Table 5-7 Dip Switch – I/O Module Corresponding Positions
MODULE Switch 1 Switch 2 Switch 3 Switch 4 IN range OUT range
1
st
0 0 0 0 I096 ~ I143 O096 ~ O127
2
nd
1 1 0 0 I144 ~ I191 O144 ~ O175
3
rd
0 1 1 0 I192 ~ I239 O192 ~ O223
4
th
1 0 0 1 I240 ~ I255 O240 ~ O255
Module Board 4 can control 16 unit of Inputs and 16 units of Outputs.
I/O related scope when using with Operation Panel 2:
Table 5-8 H6D / H9D Controller I/O Corresponding Scope
IO range
Board Switch 1 Switch 2 Switch 3 Switch 4 Input range Output Range
1
st
0 0 0 0 I096 ~ I143 O096 ~ O127
2
nd
General Purpose Secondary Control Panel I144 ~ I191 O144 ~ O175
3
rd
0 1 1 0 I192 ~ I239 O192 ~ O223
4
th
1 0 0 1 I240 ~ I255 O240 ~ O255
When use 2
nd
control panel, 2
nd