HUST CNC H6D-T Manual
5 - 30
5.6.7 W iring of System AC Power Supply
In order to avoid controller anomalies caused by voltage fluctuations, it is
recommended to provide sequential differences for the ON/OFF of the CNC power
and Servo power.
1. SERVO ON signal shall be activated in a slight delay after the activation of system
power supply, when the latter is stabilized.
2. Before switching off the system power supply, provide a delay for switching off the
SERVO ON signal first.
Fig.5-36 Wiring of System AC Power Supply
R TS
To CPU Power supply R
To CPU Power supply T
AC220V R
AC220V S
AC220V T
Servo
Driver
Fan
power-off
power-on
Power-On Relay
Powe
-On Timer Relay
AC 220V R T0 Servo AMP Power TB P
AC 220V S T0 Servo AMP Power TB N
CNC Power-on
Time
Servo Power-on
Time
servo on delay
Power off delay