6 Error Message
6 - 1
6 Error Messages
When an error occurs in the execution of an HUST H6D series controller, an error
message will appear in the LCD screen as shown in Fig.10-1. Possible error messages
regarding the HUST H6D series controller, together with their remedies, are described
as follows.
Fig.6-1
* ERROR
Error Code Details Causes
Incorrect MCM parameter setting.
01
B Each axis returned to origin, GRID limit of the servo motor
>1024.
Remedy:
1. Check MCM parameter for correct setting or double-press to enter "MDI"
mode, execute commend G10 P1000 to delete parameter, then re-set parameter.
2. If the controller has rested for more than a year without switching on, the internal
memory will disappear. The controller will display [BT1] indicating the battery
power is low and you need to contact the dealer.
3. The Application Engineer needs to check the PLC to see if C226 is triggered in
time after changing the machine parameters.
Auto
MDI
Function Message Field
System Message Field
System ERROR message display