HUST CNC H6D-T Manual
6 - 2
Error Code Details Causes
F F value is too big.
X~C Axis follow-up error is too big.
S Spindle follow-up error is too big (>3072).
W When starting the forward-feeding function, the error is too
big.
02
D When starting double-closed circuit control, the error is too
big.
Message:
Error happens to the Circuit System where the Servo is located, which could lead to the
following abnormal situation:
1. The command transmitted by the Controller is too fast that the Servo could not
respond in time.
2. The Controller fails to receive the feedback signal.
Remedy:
1. Check the program for excessive setting of F value;
2. Check whether the Resolution setting is correct (Check items 241~ 252, MCM
parameters);
3. Check if machine or motor is obstructed. Check the wiring.
4. Check Parameter 533; the default value is 4096.
5. Check the wiring condition.
Error Code Details Causes
03 L M99 count exceeds maximum limit (#10922>#10921).
Message:
Setting of the M02, M30, or M99 counter exceeds the limit of system variables, 10921.
Remedy:
1. Double press 0 button in AUTO mode to clear the counting value.
2. Clear the system variable count of 10922 so it returns to 0, then press to
remove the error.
3. Or run G10 P201 command in AUTO or MDI mode, for clearing the system
variable (10921) to 0, then press again to clear the error.RESET
RESET