EasyManua.ls Logo

HUST CNC H6D-T - Page 255

Default Icon
352 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Error Message
6 - 3
Error Code Details Causes
A U USB/SDC error FR_DISK_ERR
B USB/SDC error FR_INT_ERR
C USB/SDC error FR_NOT_READY
D USB/SDC error FR_NO_FILE
E USB/SDC error FR_NO_PATH
F USB/SDC error FR_INVALID_NAME
G USB/SDC error FR_DENIED
H USB/SDC error FR_EXIST
I USB/SDC error FR_INVALID_OBJECT
J USB/SDC error FR_WRITE_PROTECTED
K USB/SDC error FR_INVALID_DRIVE
L USB/SDC error FR_NOT_ENABLED
M USB/SDC error FR_NO_FILESYSTEM
N USB/SDC error FR_MKFS_ABORTED
04
O USB/SDC error FR_TIMEOUT
Message
When switching the transmission mode, the system reads the errors of the external
storage equipment.
Remedy:
1. Shift the transmission mode back to RS232 Mode and then check if the external
transmission equipment, such as U Panel or SD Card, is correctly configured.
2. Make sure the USB is of FAT format and the file extension of the transferred
program is correct.
3. Consult the dealer or the manufacturer.
Error Code Details Causes
05 S Command input is wrong.
Message
Command input is wrong.
Remedy :
Check the format of the input command.