7 - 36
pressed, the block number of a single block will be renumbered according to the
setting values in Parameters 514 and 515.
Ex: S = 0 , D = 5
The program block number will be generated in the sequence: 5,10,15,20,25 …
516. Denominator of Feed-rate Multiplication Factor for MPG Test.
517. Numerator of Feed-rate Multiplication Factor for MPG Test.
Format (Default=100)
Note: If the MPG rotation speed is not proper, it can be adjusted by MCM#516,
#517. The two items are up to 5 units and it must be integer. They also can not set
as zero.
518. Handwheel direction
Format= (Default= 0).
If it is necessary to change the relation between the current handwheel rotational
direction and the axial displacement direction, it can be achieved by setting the
value to 0 or 1.
It can be adjusted separately the corresponding axial direction bit 0 =x bit 1
=y....
Example: BIT 0=1 The X-axis handwheel command is reverse, but other axes
remain at the default.
519. Set Acceleration / Deceleration Time for MPG
Format= , (Default = 64), Unit: milliseconds
Setting Range: 4~512 ms.
The motor acceleration / deceleration time is equal to MCM #519 when MPG
hand-wheel is used in JOG mode.
520. RS232C Baud Rate.
Format (Default = 38400)
Set RS232C communication speed. Choose from, 9600, 19200, 38400, 57600,
115200 Speed rate 38400 stands for 38400 bits per second.
In addition, use the following settings for your PC:
Parity -- Even
Stop Bits -- 2 bits
Data Bits – 7 bits
521. Flag to Save the Data of R000~R199 in PLC when power-off.
Format (Default=0)
Setting = 0, NOT to save.