7 MCM Parameters
7 - 35
BIT6 = 0 U axis find Home grid available, =1 U axis no need to find Home grid.
BIT7 = 0 V axis find Home grid available, =1 V axis no need to find Home grid.
BIT8 = 0 W axis find Home grid available, =1 W axis no need to find Home grid.
504. Servo Motor Acceleration/Deceleration Time, G00.
Format Unit: millisecond (Default=100)
Setting Range: 2 ~ 3000 millisecond
505. Servo Motor Acceleration/Deceleration Time (T), G01.
Format Unit: millisecond (Default=100)
Setting Range: 2 ~ 3000 millisecond.
100 milliseconds is the recommended setting for both G00 and G01.
If MCM #502 setting = 0, type of accel./decel. for G01 = exponential
If MCM #502 setting = 1, type of accel./decel. for G01 = Linear.
If MCM #502 setting = 2, type of acceleration/deceleration for G01 = "S" curve.
In this case, the actual acceleration/deceleration time is twice the setting value.
506. Acceleration/Deceleration Time for G99 Mode.
Format Unit: Millisecond (Default=100)
Setting Range: 4 ~ 3000 ms.
507. Set the spindle Acceleration/Deceleration time in master mode.
Format Unit: Millisecond (Default=100)
Setting Range: 4 ~ 3000 ms.
508. Spindle Encoder Pulse Per Revolution
Format Unit: Pulse/rev (Default=4096)
509. Set Spindle Motor RPM When Vcmd = 10 Volt.
Format Unit: RPM (Default=3000)
510. Spindle voltage command 0V output balance adjustment (open circuit).
511. Spindle voltage command slope correction (open circuit).
Format S= (Default=0), Set the reference value 2047.
512. Spindle RPM correction (based on feedback from the encoder).
513. Starting Number for Auto Generation of Program Block Number.
Format S= (Default=0)
514. Increment for Auto-generation of Program Block Number.
Format D= (Default=0)
515. If D = 0, the program block number of a single program block will not be
generated automatically.
In the Edit or Teach mode, the block number of a single block can be
automatically generated by simply press the INSERT key. If the RESET key is