HUST CNC H6D-T Manual
7 - 38
Setting 1: +/- pulse
Setting 2: in the format of Phase A or B
527. Setting the G01 speed value at booting
Format= (Default=1000)
After booting, in executing the program or MDI command, if you have not used
the F command yet, nor the current single block has designated the F value, then
use the MCM 527 value as the F value of the current single block.
528. Setting the tool compensation direction
Format= (Default=0)
0 HUST
1 FANUC
Tool-wear compensation direction - HUST: same direction; FANUC: reverse
direction.
529. It is used for adjusting the G01’s acceleration/deceleration time when the
acceleration/deceleration type is set to an “S” curve.
Format= (Default=100) in unit of millisecond (msec).
When MCM 502 2, the function can then be sustained.
Setting range 10~512 ms.
531. Line editing entry format and numeral decimal’s automatic-generating setting.
Format (default setting 0)
0 The standard mode.
1 When setting the parameter values in the system master list, the system
will automatically add a decimal point to even numbers.
Ex MCM 401 setting
Enter 1 1.000
Enter 1.999 1.999
2 Line Editing.
Ex Enter G00 X10.
Standard mode steps
Step 1 Step 2 Step 3 Step 4
GOO ENTER X10. ENTER
Line editing
Step 1 Step 2
GOO X10. ENTER
4 At editing, decimal point will be automatically generated for the variable
value.